... | ... | @@ -109,7 +109,7 @@ To use the serial service, define a `<serialConf>` block with the following conf |
|
|
|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------|
|
|
|
| `obsIds`* | One or more observer IDs for which this service should be used. Note that all IDs used here have to have a target configuration as well. | ID(s) of the observer(s) to use |
|
|
|
| `port` | Which port to use for serial communication. <br />_Note 1_: In order for port `swo` to work, the SWD debug pins (SWDIO, SWDCLK) must not be reconfigured as output pins. <br />_Note 2_: for port `serial` the `baudrate` element is requried, for port `swo` the `cpuSpeed` element is required! | Possible values: `usb`, `serial`, `swo`. For the target Tmote, the default is `usb`, for all other platforms `serial` is the default. |
|
|
|
| `baudrate` | Baud rate to use when reading. Note that baud rates higher than 460800 may not work properly on all targets, i.e. characters can get lost. Also, bit errors are more likely with higher baudrates. | Possible values: 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600, 1000000, 1152000, 1500000, 2000000, 2500000, 3000000, 3500000, 4000000. Default is 115200 |
|
|
|
| `baudrate` | Baud rate to use when reading. Note that baud rates higher than 460800 may not work properly on all targets, i.e. characters can get lost and bit errors are more likely. If you use DMA to write to UART, the baudrate should not exceed 115200. | Possible values: 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600, 1000000, 1152000, 1500000, 2000000, 2500000, 3000000, 3500000, 4000000. Default is 115200 |
|
|
|
| `cpuSpeed` | Defines the target CPU speed (required if port `swo` is selected). | Frequency in Hertz. Default is 80000000. |
|
|
|
| `remoteIp` | IP address from which serial data will be sent to node. If not specified, the serial proxy service will not be used. If left blank, the IP of the machine that registered the test will be used. <br >Notes: <br />- If your machine only has an IPv6 address, then the XML validation will fail.<br />- Timestamping will be more accurate if the proxy service is not used (no `<remoteIp>` element in the XML config). | IPv4 address |
|
|
|
|
... | ... | |