Example Datasets for PhysIO
|
|
|
===========================
|
|
|
|
|
|
The following datasets are available and can be downloaded with the toolbox in a specific [`physio-examples`](https://tnurepository.ethz.ch/physio/physio-examples) repository, which can be cloned from `git@tnurepository.ethz.ch:physio/physio-examples.git`.
|
|
|
|
|
|
Besides the raw physiological logfiles, each example contains example scripts to run physio as
|
|
|
- SPM job (`*spm_job.mat`)
|
|
|
- editable SPM job (`*spm_job.m`)
|
|
|
- plain matlab script (`*matlab_script.m`)
|
|
|
|
|
|
|
|
|
Philips
|
|
|
-------
|
|
|
|
|
|
### ECG 3T ###
|
|
|
|
|
|
Courtesy of Sandra Iglesias, Translational Neuromodeling Unit, ETH &
|
|
|
University of Zurich
|
|
|
|
|
|
4-electrode ECG and breathing belt, Philips 3T Achieva scanner
|
|
|
|
|
|
Description: Standard example; shows how to use volume counting either
|
|
|
from beginning or end of run to synchronize physiological logfile with
|
|
|
acquisition onsets of fMRI scans.
|
|
|
|
|
|
### ECG 7T ###
|
|
|
|
|
|
Courtesy of Zina-Mary Manjaly, University Hospital Zurich
|
|
|
|
|
|
4-electrode ECG and breathing belt, Philips 7T Achieva scanner
|
|
|
|
|
|
Description: The ECG data for ultra-high field data is typically much
|
|
|
noisier than at 3 Tesla. Therefore, R-wave peaks are frequently missed
|
|
|
by prospective trigger detection and not marked correctly in the
|
|
|
logfile. This example shows how to select typical R-wave-peaks manually
|
|
|
and let the algorithm find the heartbeat events.
|
|
|
|
|
|
### PPU 3T ###
|
|
|
|
|
|
Courtesy of Diana Wotruba, University and University Hospital of Zurich
|
|
|
|
|
|
PPU (finger plethysmograph) and breathing belt, Philips 3T Achieva
|
|
|
scanner
|
|
|
|
|
|
Description: Similar to ECG3T, but a plethysmograph instead of an ECG
|
|
|
was used to monitor the cardiac pulsation. Example shows how to extract
|
|
|
heart and breathing rate.
|
|
|
|
|
|
General Electric
|
|
|
-----------------
|
|
|
|
|
|
### PPU 3T ###
|
|
|
|
|
|
Courtesy of Steffen Bollmann, Kinderspital Zurich and ETH Zurich
|
|
|
|
|
|
PPU (finger plethysmograph) and breathing belt, General Electric 3T
|
|
|
scanner
|
|
|
|
|
|
Description: Similar to PPU, but acquired on a GE system with two
|
|
|
separate output logfiles for pulse oximetry and breathing amplitude,
|
|
|
sampled with 40 Hz. The quality of the signal is particularly
|
|
|
challenging, stemming from a patient population.
|
|
|
|
|
|
Siemens
|
|
|
-------
|
|
|
|
|
|
### ECG 3T ###
|
|
|
|
|
|
Courtesy of Miriam Sebold, Charite Berlin, and Quentin Huys, TNU Zurich
|
|
|
|
|
|
4-electrode ECG data, Siemens 3T scanner
|
|
|
|
|
|
Description: Similar to ECG 3T, but acquired on a Siemens system with only one logfile for ECG data. The quality of the signal is challenging, stemming from a patient population. |
|
|