... | ... | @@ -3,7 +3,7 @@ |
|
|
<br />
|
|
|
|
|
|
## The data trace results are empty
|
|
|
There are several possible reasons why the data trace results might be empty:
|
|
|
There are several possible reasons why the data trace results could be empty:
|
|
|
- Clock speed mismatch: make sure that the frequency specified in the `cpuSpeed` field of the `<debugConf>` matches the actual speed of the target CPU (master clock / SYSCLK).
|
|
|
- Invalid SWO pin config: ensure that the SWO pin is configured in SWO mode and isn't used otherwise in your target code.
|
|
|
- Clock configuration is taking too long: the MCU clock configuration in your target code must be performed as soon as possible after the power-on reset. Once initialized, the master clock (CPU clock) must not be changed for the duration of the test.
|
... | ... | |